QUALITY ROOFING SUPPLIES DELIVERED TO YOUR DOOR!

Tel: 01903 695396 Mob: 07507 598007 Email: info@roofingsupplies4u.co.uk

Klober Permo Extreme RS SK2 1.5m x 50m Roll (75M2)

More Views

Klober Permo Extreme RS SK2 1.5m x 50m Roll (75M2)

Be the first to review this product

Availability: In stock

Excl. Tax: £299.00 Incl. Tax: £358.80
Permo® extreme RS SK² - low-pitched underlay is a tear-resistant underlay. It has double, self-adhesive strips which provide a permanent seal of overlaps and immediate weatherproofing protection against wind, rain and snow.

Details

Permo® extreme RS SK² - low-pitched underlay

Permo® extreme RS SK² is a tear-resistant underlay. It has double, self-adhesive strips which provide a permanent seal of overlaps and immediate weatherproofing protection against wind, rain and snow. Klober accessories are essential when being laid as key primary barrier. These are especially coordinated with the layer and included in the warranty.

Product features & benefits ?

  • Double self-adhesive strips permit permanent wind and waterproof sealing of overlaps (shear resistance > 300 N tested) ?
  • High-temperature stability at peaks up to 100°C and highly UV-resistant ?
  • Fleece with capillary stop controls the formation of condensation water. Robust PES fleece ensures improved mechanical load capacity, thus facilitating the use on sheathing.

 Area of application Suitable for: ?

  •  Minimum roof pitch of 10° ?
  • Meets the requirements as a roof support system with improved raintightness according to ÖNORM ?
  • Can be deemed as a primary barrier as long as covered by UV protected layer eg tiles, slates, etc. ?
  • Is vapour permeable however under BS5250 is classed as HR underlay so requires ventilation

Material

Glueable two-layered underlay with monolithic TPU coating on extremely tear-resistant PES fleece

Product code / Roll size / Roll weight

KU0171-11 / 50 x 1.5m (75m2 ) / 18kg

Installation Klober recommends that the membrane is laid on a 12mm plyboard/OSB then counter-battened. Butylon tape should be laid underneath where the counter battens are due to be fixed, to seal around any nail penetrations. In accordance with BS5534 the minimum head lap of any membrane needs to be 100mm when laid on a supported roof down to 15°, the 2 adhesive strips will meet, therefore no need for any other adhesives. Below 15° the head lap would need to be 150mm, therefore, a butylon tape would be required to seal the overlaps. Contact Technical for further information.

 

Customer Reviews

Write Your Own Review

You're reviewing: Klober Permo Extreme RS SK2 1.5m x 50m Roll (75M2)

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

Need Help?

Call us:

01903 695396

07507 598007 

Email us:

info@roofingsupplies4u.co.uk

or

Click the live chat button